![]() Thus, color MV systems offer a tremendous amount of information compared to conventional instruments. There are 262,144 sensing elements (512 x 512 pixels) in a CCD camera as opposed to 3 signals in colorimeters, and a maximum of 471 signals (one for every nanometer between 360 and 830 nm of wavelength) in spectrophotometers. As such, MV provides documentation and recordkeeping.Ī significant difference between conventional colorimetry and color MV is the number of signals. Once an image is captured, it can be immediately evaluated or stored for future analysis and comparisons. The sensor in the camera is a charge-coupled device (CCD) that converts photons to electrical signals. Machine vision (MV) involves a camera connected to a computer, controlled lighting (generally in the form of a light box), and the software to control camera settings, image acquisition, and processing. A user looking for black spots in shrimp, for example, won’t find them, since they will disappear into the mix. However, this changes the appearance and potentially the color of interest of the sample. For example, shrimp may be too small to cover the viewing aperture of the instrument. Both the amount and the definition of colors are quantitative.Īnother potential problem is the size and shape of the sample. Figure 1 also shows a 512-color segmentation scheme obtained using machine vision. In reality, there are many more colors than brown. This results in a significant loss of color information. If a spectrophotometer or a colorimeter were used, the result would be the “average” color, displayed by the brown square. Consider Figure 1, where the color of peppers is measured. In such cases, color values obtained with repeated measurements on a surface or from different samples in the same batch are averaged (Joshi and Brimelow, 2002). One problem may arise when the sample has nonhomogeneous colors. There are potential disadvantages in using colorimeters and spectrophotometers that machine vision can overcome. These variables, as well as the method of calibration, the description of standards, and the preparation and presentation of samples, should be well thought out to have accurate and reproducible measurements of color of foods. The size of the viewing aperture and the illuminated area may also affect results. Specifically, the reported color of a reference tile measured by a diffuse geometry may not be reproduced exactly when the same tile is read by an instrument using the 45/0 geometry. Therefore, the user must be aware of the type of instrument, as well as the history of the color measurement of any reference tiles used to make comparisons. ![]() This makes a difference in the color values measured from a glossy vs a matte surface. Diffuse geometry instruments can measure both the diffuse and the specular reflectance. Directional instruments (also called 45/0 or 0/45 devices) measure only the diffuse reflectance coming from the sample the specular-reflected light is not measured. They view the sample differently and may generate different color results. There are two categories of instruments-directional and diffuse-based on the arrangements of the light source, the sample plane, and the detector. Tristimulus values can be converted to many other color systems. Because of this averaging, colorimeters may not actually measure what humans see in the color of objects. The resulting spectral curve is compared to a reference standard, and the result is expressed as a ratio (Joshi and Brimelow, 2002).Ĭolorimeters and spectrophotometers rely on precise knowledge of the illumination and the standard observer function defined by the Commission Internationale de L’Eclairage (CIE), the global governing body for light and color measurements, to calculate the averaged spectral data of the sample area. Spectrophotometers calculate X, Y, Z values by measuring reflectance or transmittance wavelength across the visible range. They simulate the response of the standard observer and can match most colors across the visible spectrum. Tristimulus colorimeters employ filters to convert the energy of the light reflected off of or transmitted through the sample into X, Y, and Z values that locate the color of the sample in a 3-dimensional color space. However, visual observations may be unsatisfactory due to eye fatigue, poor color memory of subjects, lack of uniform lighting and standardized viewing conditions, and unavailability of trained judges, especially for routine large-scale color quality determination (Hutchings, 1999).Ĭolorimeters and spectrophotometers have been used extensively in the food industry to quantify color. Color is an important component of food quality-consumers initially accept or reject a food based on its color and other visual attributes-and can be measured by visual, instrumental, and machine vision methods.
0 Comments
Leave a Reply. |